If you have frequent changes in coal supply, or your plant has made the changeover to low sulfur and/or low sodium coal, you may also be experiencing increased opacity or even derates related to the performance of your electrostatic precipitator. SO3 conditioning may just be the solution.

Fly ash resistivity increases when using low sodium or low sulfur fuels, such as PRB coal.  SO3 (or sulfur trioxide) conditioning helps achieve optimal dust resistivity and ESP performance – either molten or granular sulfur can work, depending on the application.  Whether molten or granular sulfur is used, Neundorfer offers unique technology to ensure improved performance. Our patented remote converters make it possible to:

  • Locate the sulfur skid near the sulfur storage, reducing transport hassles

Place the converter near the precipitator, optimizing SO3 temperatures to avoid problem pluggage and prolong catalyst life.

 

Helpful Resources

KnowledgeBase: Optimizing Corona Power

KnowledgeBase: Reducing ReEntrainment

KnowledgeBase: How Boiler Performance Impacts ESP

Our Capabilities: Analytical & Laboratory Services

Our Capabilities: Predictive Modeling

Go Back

Paper Mill Gains Operational Flexibility While Reducing Emissions

Paper Company: Optimizing Gas Flow Distribution

A paper company in Wisconsin was contemplating expensive precipitator modifications to reduce emission levels. Through modeling we discovered the same result could be achieved for much, much less by making relatively simple gas flow distribution chan ...

Read the White Paper

"With Neundorfer's help, we were able to increase fuel ash content and boost precipitator ash carbon content without raising stack emissions."

Midwest Paper Mill

Back to Top