Troubleshooting ESP Discharge Electrode Suspension

Troubleshooting ESP Discharge Electrode Suspension

This article discusses suspension considerations encountered by users of weighted wire discharge electrodes.

There are two discharge electrode frames to consider in weighted wire applications:

  1. Upper wire frame from which wires are hung.
  2. Lower wire frame which maintains horizontal stability of wires by fixing the position of the wire and its attached weight

Isolating the discharge electrode system from grounded sections of the precipitator is essential for proper performance. Electrical clearances should be maintained at a distance near the plate-to-plate distance. With 9″ plate spacing, a distance of 8″ is usually acceptable, meaning that the discharge system structure should be no closer than 8″ from the nearest ground source.

The most critical consideration in the design of discharge electrode systems is the alignment of components to set and maintain electrical clearances that maintain high operating voltages.

 

Helpful Resources

KnowledgeBase: Introduction to ESP

KnowledgeBase: ESP Troubleshooting

KnowledgeBase: Major Components Overview

Our Capabilities: Precipitator Internals

Go Back

Smart Use of Data Improves Diagnostics, Optimizes Performance

Big Data at Paper Mill

Chronic operating issues and costly technical support was plaguing a southern paper mill. There had to be a better way. By analyzing data and using modeling to generate insights into performance-based maintenance and operational strategies, Neundor ...

Read the White Paper

"Neundorfer was able to monitor performance and equipment operations, analyze the data to find correlations, and create focused actions for troubleshooting and optimization."

Integrated Paper Mill

Back to Top