Troubleshooting ESP Discharge Electrode Suspension

Troubleshooting ESP Discharge Electrode Suspension

This article discusses suspension considerations encountered by users of weighted wire discharge electrodes.

There are two discharge electrode frames to consider in weighted wire applications:

  1. Upper wire frame from which wires are hung.
  2. Lower wire frame which maintains horizontal stability of wires by fixing the position of the wire and its attached weight

Isolating the discharge electrode system from grounded sections of the precipitator is essential for proper performance. Electrical clearances should be maintained at a distance near the plate-to-plate distance. With 9″ plate spacing, a distance of 8″ is usually acceptable, meaning that the discharge system structure should be no closer than 8″ from the nearest ground source.

The most critical consideration in the design of discharge electrode systems is the alignment of components to set and maintain electrical clearances that maintain high operating voltages.

 

Helpful Resources

KnowledgeBase: Introduction to ESP

KnowledgeBase: ESP Troubleshooting

KnowledgeBase: Major Components Overview

Our Capabilities: Precipitator Internals

Go Back

Creative Approach, Thoughtful Analysis Saves Two Coal Plants

Power producer, Emissions Compliance Success Story

When the plant's initial assessment indicated MATS compliance would require high-cost upgrades, the future of two plants was uncertain. By modeling improvements over the entire process, Neundorfer identified a low-cost compliance program that would ...

Read the White Paper

"Neundorfer combined its analytical process with its application experience to identify low-cost approaches that would achieve MATS compliance."

Midwestern Coal-Fired Utility

Back to Top