Fuel Changes & ESP Performance

Fuel Changes & ESP Performance

If you have frequent changes in coal supply, or your plant has made the changeover to low sulfur and/or low sodium coal, you may also be experiencing increased opacity or even derates related to the performance of your electrostatic precipitator. SO3 conditioning may just be the solution.

Fly ash resistivity increases when using low sodium or low sulfur fuels, such as PRB coal.  SO3 (or sulfur trioxide) conditioning helps achieve optimal dust resistivity and ESP performance – either molten or granular sulfur can work, depending on the application.  Whether molten or granular sulfur is used, Neundorfer offers unique technology to ensure improved performance. Our patented remote converters make it possible to:

  • Locate the sulfur skid near the sulfur storage, reducing transport hassles

Place the converter near the precipitator, optimizing SO3 temperatures to avoid problem pluggage and prolong catalyst life.

 

Helpful Resources

KnowledgeBase: Optimizing Corona Power

KnowledgeBase: Reducing ReEntrainment

KnowledgeBase: How Boiler Performance Impacts ESP

Our Capabilities: Analytical & Laboratory Services

Our Capabilities: Predictive Modeling

Go Back

Creative Approach, Thoughtful Analysis Saves Two Coal Plants

Power producer, Emissions Compliance Success Story

When the plant's initial assessment indicated MATS compliance would require high-cost upgrades, the future of two plants was uncertain. By modeling improvements over the entire process, Neundorfer identified a low-cost compliance program that would ...

Read the White Paper

"Neundorfer combined its analytical process with its application experience to identify low-cost approaches that would achieve MATS compliance."

Midwestern Coal-Fired Utility

Back to Top